<LOGO>
FM Transmitter Measurement Report
Created: 2026-08-23 06-56-17
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.6 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 64 kHz 16610 9,0608
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,2 dBr 4,33 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 64 kHz MIN: 12 kHz % above 76 kHz: 9,0608 Acquired: 2026.08.23 6.55.14 Total samples: 16610 Equivalent time: 0:13:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,1 dBr MIN: 3,2 dBr AVE: 4,33 dBr % above 12,2 dBr: 0,0 Last value: 3,7 dBr (2026.08.23 6.55.14) 06.42 06.44 06.46 06.48 06.50 06.52 06.54 0 2 4 6 Pm [dBr]